PD1041 - Hardened Surge Protection Device – RJ45

$89.00
In stock
Only 1 left
SKU
PD1041

PD1041
Hardened Surge Protection Device – RJ45

  • Provides pair-to-pair protection through RJ45 connector
  • Compatible with 10/100/1000BASE-T and PoE


PD1041
Hardened Surge Protection Device – RJ45

Provides pair-to-pair protection through RJ45 connector
Compatible with 10/100/1000BASE-T and PoE
More Information
Mount Type DIN-Rail
Product Class Industrial/Hardened
Operating Temperature Range -40 to 75°C (-40 to 167°F)
Industry Standards IEC 61643, UL 497B
Maximum continuous operating voltage UC ≤ 3.3V DC
Maximum continuous voltage UC (wire-wire) ≤ 3.3 V DC (± 60 V DC/PoE+)
Maximum continuous voltage UC (wire-ground) ≤ 180 V DC
Nominal current IN ≤ 1.5 A (25 °C)
Operating effective current IC at UC ≤ 1 μA
Residual current IPE ≤ 8 μA
Nominal discharge surge current In (8/20) μs (Core-Core) 100 A
Nominal discharge surge current In (8/20) μs (Core-Earth) 2 kA (per signal pair)
Total surge current (8/20) μs 10 kA
Nominal pulse current Ian (10/700) μs (Core-Core) ≤ 40 A
Nominal pulse current Ian (10/700) μs (Core-Earth) ≤ 160 A
Output voltage limitation at 1 kV/μs (Core-Core) spike ≤ 85 V (PoE)
Output voltage limitation at 1 kV/μs (Core-Earth) spike ≤ 700 V
Output voltage limitation at 1 kV/μs (Core-Core) static ≤ 9 V
Output voltage limitation at 1 kV/μs (Core-Earth) static ≤ 700 V
Output voltage limitation at 100V/s (Core-Core) ≤ 9 V
Output voltage limitation at 100V/s (Core-Earth) ≤ 300 V
Output voltage limitation at 100V/μs (Core-Core) ≤ 9 V
Output voltage limitation at 100V/μs (Core-Earth) ≤ 600 V
Residual voltage at IN, (conductor-conductor) ≤ 15 V • ≤ 100 V (PoE)
Voltage protection level Up (Core-Core) ≤ 9 V (B2 - 1 kV/25 A • ≤ 100 V (B2 - 1 kV/25 A - PoE) • ≤ 15 V (500 V/100 A)
Voltage protection level Up (Core-Earth) ≤ 600 V • ≤ 700 V (C2 - 4 kV/2 kA)
Response time tA (Core-Core) ≤ 1 ns
Response time tA (Core-Earth) ≤ 100 ns
Input attenuation aE, sym. 1 dB (≤ 250 MHz)
Near-end crosstalk attenuation ≤ 35 dB (At 250 MHz / 100 Ω)
Cut-off frequency fg (3 dB), sym. in 100 Ohm system > 500 MHz
Capacity (Core-Earth) typ. 2 pF (f= 1 MHz / VR= 0 V)
Surge carrying capacity in acc. with IEC 61643-21 (Core-Earth) B2 (4 kV / 100 A) • C2 (4 kV / 2 kA) • D1 (1 kA)
Connection (input / output) RJ45 connector / RJ45 connector

Related products

Check items to add to the cart or
This is the privacy policy sample page.
It was created automatically and do not substitute the one you need to create and provide to your store visitors.
Please, replace this text with the correct privacy policy by visiting the Customers > GDPR > Privacy Policy section in the backend.