PD3041 - Hardened Surge Protection Device – RJ11/Terminal Block

$100.00
In stock
Only 39 left
SKU
PD3041

PD3041
Hardened Surge Protection Device – RJ11 & Two Wire Terminal Block

  • Provides pair-to-pair protection through RJ11 connector & terminal block
  • Can be installed in control cabinet

PD3041
Hardened Surge Protection Device – RJ11 & Two Wire Terminal Block

Provides pair-to-pair protection through RJ11 connector & terminal block
Can be installed in control cabinet
More Information
Mount Type DIN-Rail
Product Class Industrial/Hardened
Operating Temperature Range -40 to 75°C (-40 to 167°F)
Industry Standards IEC 61643, UL 497B
Maximum continuous operating voltage UC ≤ 185VDC
Maximum continuous voltage UC (wire-wire) ≤ 185VDC
Maximum continuous voltage UC (wire-ground) ≤ 185VDC
Nominal current IN ≤ 380mA (25 °C)
Operating effective current IC at UC ≤ 6 μA
Residual current IPE ≤ 4 μA
Nominal discharge surge current In (8/20) μs (Core-Core) ≤ 5 kA
Nominal discharge surge current In (8/20) μs (Core-Earth) ≤ 5 kA
Total surge current (8/20) μs 10 kA
Nominal pulse current Ian (10/1000) μs (Core-Core) ≤ 100A
Nominal pulse current Ian (10/1000) μs (Core-Earth) ≤ 100A
Nominal pulse current Ian (10/700) μs (Core-Core) ≤ 150A
Nominal pulse current Ian (10/700) μs (Core-Earth) ≤ 150A
Output voltage limitation at 1 kV/μs (Core-Core) spike ≤ 250 V
Output voltage limitation at 1 kV/μs (Core-Earth) spike ≤ 250 V
Residual voltage at IN, (conductor-conductor) ≤ 120 V
Residual voltage at IN, (conductor-ground) ≤ 120 V
Voltage protection level Up (Core-Core) ≤ 300 V (B2 – 100A) • ≤ 300 V (C1 – 500A) • ≤ 300 V (C2 – 5kA)
Voltage protection level Up (Core-Earth) ≤ 300 V (B2 – 100A) • ≤ 300 V (C1 – 500A) • ≤ 300 V (C2 – 5kA)
Response time tA (Core-Core) ≤ 100 ns
Response time tA (Core-Earth) ≤ 100 ns
Input attenuation aE, sym. Typ. 0.5 dB (≤ 5 MHz) • Typ. 0.3 dB (≤ 8 MHz / 150Ω) • Typ. 0.3 dB (≤ 2.5 MHz / 600Ω)
Near-end crosstalk attenuation ≤ 35 dB (At 250 MHz / 100 Ω)
Cut-off frequency fg (3 dB), sym. in 100 Ohm system Typ. 50 MHz
Resistance in series 3.3 Ω ±10%
Surge carrying capacity in acc. with IEC 61643-21 (Core-Earth) B2 (4kV / 100A) • C1 (1kV / 500A) • C2 (10kV / 5 kA) (Terminal block) • C2 (6kV / 3kA) (RJ11) • D1 (1 kA)
Connection (input / output) RJ11 connector or Terminal Block